- Philips M2601A S03 (EASI) ECG Telemetry Transmitter
Philips Telemetry User Manual
The IntelliVue MX40 is a wearable patient monitor. It is designed to support ambulatory patients for continuous ECG and optionally, SpO 2 and impedance respiration. Adobe photoshop 2018 mac download. The short-range radio option allows connection to the IntelliVue Cableless Measurements or an IntelliVue patient monitor for. Download 4549 Philips Monitor PDF manuals. User manuals, Philips Monitor Operating guides and Service manuals. Set up telemetry from central monitor and ensure it is displayed on the bedside monitor – (see Philips Telemetry Training Guide) (attach a link to Philips telemetry set up) Adjust ECG settings as ordered; For monitor set up - Lead 1 is used to diagnose QRS complex Lead 2 is used to diagnose atrial activity and to monitor heart rate. Configuration choices. For specific information on using the Philips Telemetry System, the Philips IntelliVue Telemetry System, or the IntelliVue MX40, please refer to your appropriate telemetry system Instructions for Use manual. The on-line Information Center Help provides instructions for completing basic tasks and troubleshooting problems.
Product Description
The Philips M2601A Telemetry system transmitter sends continuous ECG and SpO2 measurements to the IntelliVue Information Center, where the measurements are captured, analyzed, displayed, and stored. El capitan os x dmg download.
The basic setup comes with 3-lead or 5-lead capability. The ECG-only transmitter is particularly light and comfortable for patients. Upgraded transmitters combine standard and EASI derived 12-lead ECG monitoring on a single device, run on easily replaceable AA batteries, and provide audio feedback for many tasks, including 'power on' and SpO2 spot check.
Features:
- Frequency of 460-480 MHz or 608-614 MHz WMTS
- Lightweight—less than ½ lb.
- Standard ECG configuration with 3- or 5-lead capability
- EASI ECG configuration used for transmitters that work with central stations that are capable of converting a 5-wire lead set signal to 12 lead analysis by having EASI version software installed at the central station.
- SpO2 configuration used for transmitters that are used with SpO2 sensors.
Add SpO2 Probe (Only Available with S02 Model):
Warranty Information
Find Similar Products by Category
The Philips M2601A Telemetry system transmitter sends continuous ECG and SpO2 measurements to the IntelliVue Information Center, where the measurements are captured, analyzed, displayed, and stored. El capitan os x dmg download.
The basic setup comes with 3-lead or 5-lead capability. The ECG-only transmitter is particularly light and comfortable for patients. Upgraded transmitters combine standard and EASI derived 12-lead ECG monitoring on a single device, run on easily replaceable AA batteries, and provide audio feedback for many tasks, including 'power on' and SpO2 spot check.
Features:
- Frequency of 460-480 MHz or 608-614 MHz WMTS
- Lightweight—less than ½ lb.
- Standard ECG configuration with 3- or 5-lead capability
- EASI ECG configuration used for transmitters that work with central stations that are capable of converting a 5-wire lead set signal to 12 lead analysis by having EASI version software installed at the central station.
- SpO2 configuration used for transmitters that are used with SpO2 sensors.